Adjustable Duty Cycle Square Wave generator

2 uafhængige generatorer 
Kan styres via trykknapper, eller RS232 interface 
Kan styre 2 servomotorer

Flere detaljer

0021/1948

Tilgængelighed: Denne vare er ikke længere på lager


Giv mig besked, når varen er tilgængelig

DKK 30,00 inkl. moms

7 andre varer i samme kategori:

Frequency range: 1Hz ~ 150KHz
Output amplitude: Default 5Vp-p
Duty Cycle in the range: 0 to 10

Parameter settings:

Module has three buttons [Set], [Up], [Down];
Press [Set] key to switch the display four parameters (FR1: PWM1 frequency; dU1: PWM1 duty cycle; FR2: frequency of PWM2; dU2: PWM2 duty cycle), before the handover parameters, there will be corresponding parameter name flash.

Press [Up], [Down] keys to modify the current parameter value (long press can quickly add or subtract fast).
Two PWM each have three preset frequency, the frequency display interface, long press [SET] key to switch between three types of frequencies, three kinds of frequency duty cycle is the same value. (XXX: range 1Hz ~ 999Hz; XX.X: range 0.1Khz ~ 99.9Khz; X.X.X .: range 1Khz ~ 150Khz,).

Scope:
As square wave signal generator which generates a square wave signal;
to provide a signal to the stepping motor driver;
Adjustable pulse generation for chip use;
produce variable pulse signal, the control-related circuit (PWM dimming, speed).
Fifth, the serial control
Baud rate: 9600 bps
Data bits: 8
Stop bits: 1
Parity bit: none
Flow control: none
1, set the PWM frequency
"S1FXXXT": setting PWM1 frequency of XXX HZ (001 ~ 999)
"S1FXX.XT": set the frequency of PWM1 XX.X KHZ (00.1 ~ 99.9)
"S1F: X.X.X.T": setting PWM1 frequency of XXX KHZ (0.0.1 ~ 1.5.0..)
'S1': PWM1
'S2': PWM2
'F': Frequency
'D': Duty Cycle
'T' is the end flag
Set the PWM duty cycle
"S1DXXXT": setting PWM1 duty cycle XXX; (001 ~ 100)
"S2DXXXT": set PWM2 duty cycle XXX; (001 ~ 100)
Setting successful return: DOWN;
Setting failback: FALL.